Startup of the Sysview for DB2 Data Collector terminates with RC=0052
search cancel

Startup of the Sysview for DB2 Data Collector terminates with RC=0052

book

Article ID: 112108

calendar_today

Updated On:

Products

Bind Analyzer for DB2 for z/OS SQL-Ease for DB2 for z/OS SYSVIEW Performance Management Option for DB2 for z/OS Plan Analyzer for DB2 for z/OS Subsystem Analyzer for DB2 for z/OS

Issue/Introduction

 The startup of one of the Sysview for DB2 Data Collectors terminates with a RC=0052.

Environment

Release:
Component: IDB2

Cause

In this scenerio, the cause of the immediate termination upon startup of the Sysview for DB2 Data Collector                        
with RC=0052 was due to the DC STC not providing a DBLOC parameter.       

Resolution

Providing a DBLOC parameter on the DC STC proc to correlate to the APPLS member's specification for the given Data Collector proved corrective.