Issue/Introduction
Sometimes accessing the VTOC on the Dynam panels we receive the following message:
0S03I PROGRAM CHECK INTERRUPTION - HEX LOCATION 0049B470 -
INTERRUPTION CODE 10 - SEGMENT-TRANSLATION EXCEPTION
0S00I SUB CAYDSERV CANCELED
0S07I PROBLEM PROGRAM PSW = 070D0000 8049B470
0S29I DUMP STARTED
0S30I DUMP STARTED. MEMBER=DF200045.DUMP IN SUBLIB=SYSDUMP.F2
1I49I DUMP LIBRARY FULL
After the error we can't access any Dynam panel and have to recycle CICS.
Environment
Two weeks ago we migrated from z/VSE 3.1.2 to z/VSE 6.1.
Required PTF's RO11221, RO12514, RO24750, RO24752, RO24753 are applied.
This error has occurred two times.
Resolution
Apply PTF RO40769 which will prevent the abend when displaying a VTOC.
You will need to cycle CICS, or, NEWCOPY the three phases to activate.
A system IPL is not required.
Additional Information
See CM-UE problem #8 that's associated with the PTF for additional information.