DatacomDATACOM - ADCISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertware
Issue/Introduction
When running a DBUTLTY MASSADD function in version 15.1, the documentation identifies a function (OPTION2=DUPS_IGN) that would be helpful. However running this option gave us an error: OPTION2=DUPS_IGN DB10011E - KEYWORD INVALID FOR FUNCTION SELECTED
Why does this documented option not work?
Environment
Release: DBCISF00200-15.1-Datacom-Database-Option for CICS Services Component:
Resolution
The ability to use DUPS_IGN on DBUTLTY MASSADD is an enhancement to version 15.1,that was provided through RO90903 (DB 15.1 #19 [OS]), "DB 15.1 NEW FEATURE SUPPORT" (Published 07 Jul 2016)
Without this solution applied, the above error message will be produced.
Note that RO90903 is marked in error, and the correcting PTF is RO91141 (DB 15.1 #23 [OS]), "MUF ABORTS WITH A S0C4 DBEIPPR+1D9A" (Published 27 Jul 2016) *** HYPER ***
To use this new feature, apply RO91141 if it is not in your system.
Additional Information
As always, please contact CA Technologies support for CA Datacom if you have further questions.