UIM HA Hub Upgrade

book

Article ID: 111156

calendar_today

Updated On:

Products

NIMSOFT PROBES DX Infrastructure Management

Issue/Introduction

When upgrading UIM where a High Availability (HA) hub is configured do we need to run the installer in the HA hub?

Environment

Release:
Component: CAUIM -HA probe

Resolution

No. Once the Primary hub is upgraded you can deploy the upgraded Hub, robot and probes to the HA hub

Additional Information

Because of database schema changes implemented in UIM 9.02, fail overs to the HA backup hub need to be prevented until all of the probes on the HA backup hub have been upgraded to the 9.02 versions. 

Allowing an earlier version of any of the UIM probes that write to any of the data base tables (like the data_engine and qos_processor) may cause corruption in these tables  