SYSTEM ABEND FF2 when trying to browse or edit an IMS DB
book
Article ID: 111026
calendar_today
Updated On:
Products
File Master Plus for IMSFile Master Plus for DB2 for z/OS
Issue/Introduction
SYSTEM ABEND FF2 when trying to browse or edit an IMS DB via CA File Master for IMS
Environment
Release: Component: FMIMS
Resolution
An SFnn abend means that SVC X’nn’ isn’t installed. In this example SVC 242 (X'F2'). The SVC number is embedded in SDFSRESL member DFSVC000. You may have to update that library or use one that has the correct SVC number generated. That means, the CA File Master for IMS user has to check the environment - panel 0.5 (IMS ENV). Adding the correct IMS SDFSRESL at the RESLIB #1 line could resolve the problem. Otherwise you have to contact your IMS system administrator.
Additional Information
The information on this IBM page could be probably helpful and a good starting point: https://www.ibm.com/support/knowledgecenter/en/SSEPH2_15.1.0/com.ibm.ims15.doc.sag/system_admin/ims_svc_imsmodules.htm