Issue/Introduction
During ZDU process to upgrade Automic Workload Automation from 12.0.5 to 12.0.5hf2: At the step of starting up new WP & CP, new processes do not start successfully, below error message is found in the logs:
20180731/105705.093 - U00005134 Component 'WP' is newer than the registered one. Start your system again using mode 'cold start'.
Environment
Release: Component: AAUTEN
Cause
Investigation:
Execute the follow query:
Select * from UC_ZDU
Result shows only 1 entry of current (old) version
<Please see attached file for image>
Instead if should show:
<Please see attached file for image>
Cause:
DB was not loaded correctly, hence the query to UC_ZDU returned no corresponding version.
Resolution
It is required to upgrade DB schema & initial data properly even if it's a hotfix release.
Please download the corresponding target package and load correct db schema & initial data (by using DBLoad Utility) before proceed to steps of starting up new Automation Engine Processes (CP&WP)
Additional Information
Please find the Upgrading steps for Zero Downtime Upgrade here.