Issue/Introduction

UIM alarm traps are missing from 2 of 6 devices in snmpgtw profiles.  All 6 profiles are active.

Cause

The device profiles which were not receiving traps were missing the trapmap key value.  This causes the probe to skip these active profiles.

Environment

UIM 8.51
snmpgtw all releases through 1.40

Resolution

1. From the snmpgtw probe's Configure GUI, select the Profiles tab
2. Select each problematic profile from the Configured Profiles section in the left-hand pane.
3. In the Trap mapping tab in the right-hand pane of the selected profile, enter a value of 0 (zero) for the Default.