S0C1 in TSO Test Facility (0C1)
search cancel

S0C1 in TSO Test Facility (0C1)

book

Article ID: 109060

calendar_today

Updated On:

Products

Gen Gen - Workstation Toolset Gen - Host Encyclopedia Gen - Run Time Distributed

Issue/Introduction

We have recently made a data model change but the change does not work. We traced the client - no issues found. We then created a batch copy of the server so that we can trace through the server. When tracing we get the following abend: CEE3201S The system detected an operation exception (System Completion Code=0C1 ).
From compile unit WAA10191 at entry point WAA10191
at compile unit off set -23841000 at entry offset -23841000 at address 00000000. Possible Bad Branch:
Statement: Offset: +00000972 IEA995I SYMPTOM DUMP OUTPUT USER COMPLETION CODE=4039 REASON CODE=00000000 TIME=13.52.29 SEQ=60381 CPU=0000 ASID=016E
PSW AT TIME OF ERROR 078D1400 89A57A82 ILC 2 INTC 0D
NO ACTIVE MODULE FOUND NAME=UNKNOWN DATA AT
PSW 09A57A7C - 00181610 0A0D58D0 D00498EC GR 0: 84000000 1: 84000FC7 2: 0017BC88 3: 00000000 4: 09A4BAE0 5: 09A57A82 6: 0012C358 7: 2302F1E8 8: 0017BC88 9: 0017B764 A: 0017C5B7 B: 89A579A8 C: 0016E430 D: 0017EED8 E: 89A4AA96 F: 00000000 END OF SYMPTOM DUMP <> LEAID ENTERED (LEVEL 12/21/2015 AT 17.45) 

Environment

z/OS

Resolution

Customer using the TSO Test Facility. The pstep is statically linked and the CABs are dynamically linked. The install was for batch so the CABs were in the batch dynamic library. The pstep was in a different lib.  Need to specify libraries for all executed modules in the Test Facility..