"COMMUNICATION ATTRIBUTES DIFFER" alarms on application and port models in Spectrum
book
Article ID: 107120
calendar_today
Updated On:
Products
CA SpectrumDX NetOps
Issue/Introduction
"COMMUNICATION ATTRIBUTES DIFFER FROM PARENT" and "COMMUNICATION ATTRIBUTES DIFFER ON PORT OR APPLICATION" alarms on application and port models
Environment
Any Spectrum version
Cause
One of the communication attributes on the application or port model does not mirror the value of that attribute on the parent device model.
Resolution
The event associated with the alarm will specify which attribute value is different. The following example specifies the network address on the application model is different from the network address on the parent device model:
In this example, update the network address on the application model to the same value as the network address on the device model