DatacomDATACOM - ADCISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertware
Issue/Introduction
SMP/e APPLY CHECK of a PTF results in no error and COND 0 but APPLY fails with:
Multiple.... IEW2552E 4607 RECORD NUMBER n OF THE CURRENT OBJECT MODULE HAS AN INVALID LENGTH FIELD.
Resulting in link-edit failure... GIM23901E ** LINK-EDIT PROCESSING FOR SYSMOD sysmod FAILED FOR MODULE module IN LMOD loadmod IN THE SMPLTS LIBRARY
What is causing the SMP/e APPLY to fail with IEW2552E INVALID LENGTH FIELD when the APPLY CHECK gave no errors?
Environment
z/OS
Resolution
The RECEIVED PTF is somehow corrupted. The binary PTF file may not have been properly or completely downloaded or uploaded.
Download the solution again from SUPPORT.BROADCOM.COM. SMP/e REJECT, then RECEIVE and APPLY the solution.