How to Perform a UIM discovery reset when integrated with Spectrum
search cancel

How to Perform a UIM discovery reset when integrated with Spectrum

book

Article ID: 106021

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

When integrated with Spectrum through the spectrumgtw probe, UIM discovery resets will adversely affect this integration.  Need a procedure to reset the UIM discovery and Spectrum integration.

What is the process to follow when a UIM discovery reset is called for, but UIM is integrated with Spectrum through the spectrumgtw probe?

Environment

UIM/UMP 8.51

Resolution

- From Spectrum OneClick, disable the UIM integration.
- Remove all UIM alarms and synchronized devices from Spectrum
- Disable the spectrumgtw probe in UIM
- Restarted Spectrum OneClick to start with a clean slate.
- Reset the discovery in UIM
See the following Knowledge Document for this procedure and follow the instructions in the Remove Master Devices link found under the Additional Information section:

KB000014901 : Does UIM Delete devices in Spectrum ?

- Wait for the inventory to reappear in UIM
- Start the spectrumgtw probe
- Enable the UIM integration in Spectrum OneClick again