CISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesDatacom/ADCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertwareCompress Data Compression for MVSCompress Data Compression for Fujitsu
Issue/Introduction
You are applying RO97512 but you have a lot of errors during the linkedit step.
GIM41802I JCLIN PROCESSING WAS SUCCESSFUL FOR SYSMOD RO97512. GIM42001I THE FOLLOWING CONDITIONS FOR SYSMOD RO97512 WERE NOT SATISFIED, BUBUT WERE IGNORED BECAUSE THE BYPASS OPERAND WAS SPECIFIED. PROCESSING CONTINUES. GIM35966I SYSTEM HOLD DDDEF ORIGINATED BY SYSMOD RO97512 WAS BYPASSED. GIM69012I RETRANSFORMATION OF HFS CCSOPJEX ON LIBRARY SYSUT1 WAS SUCCESSFUL FOR SYSMOD RO97512. GIM69167I HFSCOPY PROCESSING TO THE CAW0ZFS1 LIBRARY WAS SUCCESSFUL FOR HFS CCSOPJEX IN SYSMOD RO97512. THE RETURN CODE WAS 00. DATE 18.188 - TIME 00:14:07 - SEQUENCE NUMBER 000001. GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD RO97512 FAILED FOR MODULE MODULE CCSOPEEM IN LMOD CCSOPEXM IN THE CAW0PLD LIBRARY. THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 18.188 - TIME 00:14:07 - SEQUENCE NUMBER 000002 - SYSPRINT FILE SMP00004. GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD RO97512 FAILED FOR MODULE CCSOPERR IN LMOD CCSOPEXM IN THE CAW0PLD LIBRARY. THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 18.188 - TIME 00:14:07 - SEQUENCE NUMBER 000002 - SYSPRINT FILE SMP00004. GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD RO97512 FAILED FOR MODULE CCSOPHBM IN LMOD CCSOPEXM IN THE CAW0PLD LIBRARY. THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 18.188 - TIME 00:14:07 - SEQUENCE NUMBER 000002 - ... GIM30216I APPLY PROCESSING FAILED FOR SYSMOD RO97512. SYSTEM UTILITY PROCESS GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 08.
Even after performing the hold actions and rejecting RO97512 and getting a new PTF, you have the same problem.
Why do I have the IEW2506E error message when applying RO97512?
Environment
Common Services 14.1 - z/OS 2.2 -
Resolution
It is a SMP/E problem:
The COMPACT option in SMPE will compact the inline element data within SYSMODs in the SMPPTS. The default is YES.
However, several bytes in the element data are corrupted after expanded during the APPLY processing.
That's why you get error IEW2506E in the linkedit step.
You have to change the option to COMPACT(NO) in the global zone.
Then reject and receive RO97512 again. The apply process is now successful.