Install Mainframe Application Tuner (MAT) 11.0 and am not getting data from a CICS monitor.
Trying to use MAT 11.0 to get information from CICS but gets the monitor gets the message "no data available".
CICS level is CTS 5.3.
One must be sure to not just install the MAT 11.0 at BASE and then attemp to IVP. CTS 5.3 is not supported in MAT 11.0 at BASE!
Here are some indications that this is your situation:
A) When we initiated the CA MAT capture processing for CICS transaction under CICS V5.3 (Release 700), there is a message into CICS log:
TN0837S Unsupported CICS version 0503 e na log do MAT, a mensagem: TN0494W CICS routine not found for profile: xxxx.
Working with CICS support team we noticed that this message is issued by module T00CPLT.
B) Also Checking the MAT loadlib named: HLQ.MAT11.CEESPLD - we noticed that there are no routines for CICS 5.3 into it.
TC69CMPX
TC69CMSG
TC69CPLT
TC69CREQ
TC69CRTE
TC69CSTO
TC69DSAB
TC69ENAB
TC69EXBG
TC69FSET
TC69ICMT
TC69NTRT
TIMSECP
TIMSMAIN
TIMSPC01
TIMSRTBL
TIMSTBRD
TIMSTBWT
TNACHECK
One needs AT THE VERY LEAST the Incremental PTFs. The PTF that supplies CTS 5.3 support is:
APAR #: RO87758
Product: MATUNE Release: 11.0
Title: MAT V11 INCREMENT 1
ENHANCEMENT DESCRIPTION:
Increment 1 provides:
* Toleration Support
> COBOL v5.2
> IMS v14.1
> CTS v5.3
> PL/I v4.5
> zOS C++ Compiler
> v2.1
> v2.2
> zNext Processor
* Ease of Use Enhancements
> CICS Parameters
> DB2 parameters
* Graphical User Interface Enhancements
> Filtering Criteria
> Profile Deletion
> Use of Schedules (Phase I)