FDR Innovation had changed the process in which they call the TLMS TLMSCMD module. This change created a conflict that was not discovered until the new processes of the TLMS upgrade were implemented.
An OPEN command by the main module is issued for TLMSCMD via
CMNDKEY=CMNOPEN, CMNDMODE=TLMSONLN
to be carried out by module #2.
Another requested OPEN without issuing a CLOSE for the first OPEN call was being issued.
They have added an CLOSE to TLMSCMD before the next open.
The error will look like this.
IEC205I TAPEOUT,WEBBT08M,MIGRATE,FILESEQ=1, COMPLETE VOLUME LIST,
DSN=XXX.TEST.XXX.XXXXXXX.XXXXXXX,VOLS=#####,TOTALBLOCKS=####
TLMSCMND : CALL TO (INIT_SUB) FAILED
TLMSCMND : INIT_SUB FAILURE RC IS NOT 8.
FDR Innovation has developed a patch P-49.3016 to fix this error. The patch is available from FDR support.