In the process of converting to DATACOM 15.1 it has been broken into two phases to simplify as noted.
Phase one has been completed by running job AXACTUPG successfully.
The process of completing phase 2 is by running jobs AXACTALC, AXACTDD1 and AXACTDD2.
After all was successful, it was noticed that the CXX DBID 1000 CASYSTEMTABLES DEFINITION
was still at VERSION 14.0. There was a 4th job AXACTDYN that is not mentioned in the
current DATACOM/AD 15.1 manuals.
Trying to run this job against the DATACOM for CA11 which fails with:
DB00605E - DBUTLTY COMM CONSOLE BAD CONTEXT - SYSTEMDBID_DELETE.
PTF RO95838 removes the need to execute AXACTDYN.
The Datacom/AD 15.1 does not document job AXACTDYN since it is not used anymore.
DBID 100 will show the following for example:
DB00915I - CXX DBID 1000 CASYSTEMTABLES DEFINITION VERSION 14.0 CHANGE LEVEL 0
instead of
DB00915I - CXX DBID 1000 CASYSTEMTABLES DEFINITION VERSION 15.1 CHANGE LEVEL 0.0
Datacom/AD 15.1 does not use the new Dynamic System Tables coming with 15.1 upgrade
The AXACTDYN job has been removed to simplify the Active Upgrade process and prevent error such as:
DB00605E - DBUTLTY COMM CONSOLE BAD CONTEXT - SYSTEMDBID_DELETE.