Why I'm still seeing OPS4111O error messages after having increased AOFFIRELIMIT on the panel 4.1.1?

book

Article ID: 103441

calendar_today

Updated On:

Products

CA OPS/MVS Event Management & Automation

Issue/Introduction



Why I'm still seeing OPS4111O error messages after having increased AOFFIRELIMIT on the panel 4.1.1?

Environment

Release:
Component: OPSMVS

Resolution

If the parameter AOFFIRELIMIT is changed the rule will need to be disabled / enabled to pick up the new value .      

Optionally it is possible to increase the limit for one specific rule by including the OPTIONS statement in the )INIT section of a rule:

)INIT
OPTIONS "FIRELIMIT=nnnnn"

or

OPTIONS "NOFIRELIMIT"                                     

Additional Information

https://techdocs.broadcom.com/us/en/ca-mainframe-software/automation/ca-ops-mvs-event-management-and-automation/14-0/using/using-automated-operations-facility-aof-rules/building-and-controlling-aof-rules.html