The client is upgrading to VSE 6.2 for CA Intertest for CICS VSE. Is fix TE61063 and same as fix T561063?
book
Article ID: 103178
calendar_today
Updated On:
Products
InterTest - CICSInterTest - BatchInterTest VSE - CICS
Issue/Introduction
When upgrading to VSE 6.2 the client is required to apply fixes TC23605, TC23606, T561063 to CA Intertest for CICS VSE release 6.0 . The client already has fix TE61063 applied for a previous problem which alters the same instructions as fix T561063. Is fix T561063 is permanent version for TE61063?
Environment
VSE
Resolution
Fixes TE61063 and T561063 are identical fixes. So the fix required for VSE 6.2 is already applied.
Below is fix TE61063.
CORR 0202-IRH08-VS2:TE61063
CORR 0202-IRH08-VS2:TE61063 REQ PRE=(QO82058,RO01079) AFF PHASE=IN25PGMS ALT 007CF4 00018000:0005FFFF ALT 00B392 F2F1F7:F2F2F1
Below is fix T561063
// JOB T561063 * * PRODUCT: CA-INTERTEST-VSE REALIA II HTO RELEASE: 6.0 * * PROB #: 000706 FN: T561063 FT: INTCOM DATE: 16 JUL 2008 * * CICS411 IADS ABEND IN IN25PGMS WHEN MONITORING. * --------------------------------------------------- * * PROBLEM RESOLUTION: Apply the following PTF to the system. * Reload any resident modules, or re-IPL if necessary. * ***NOTE*** Retain the printed output for reference. * * REQ PRE=(QO82058,RO01079) * // DLBL IJSYSHF,'INSTALL.HISTORY.FILE',99/365,SD ,99/365,SD // EXTENT SYS011,VOLIDX,1,0,XTN1,XTN2 // ASSGN SYS011,DISK,VOL=VOLIDX,SHR // DLBL CAIILIB,'INSTALL.LIBRARY.NAME' // EXTENT ,VOLIDX // EXEC MSHP,SIZE=768K CORR 0202-IRH08-VS2:TE61063 REQ PRE=(QO82058,RO01079) AFF PHASE=IN25PGMS ALT 007CF4 00018000:0005FFFF ALT 00B392 F2F1F7:F2F2F1 /* /&