We have several IMS subsystems v13 in the same LPAR. Some of these IMS subsystems were upgraded to v15. OPSVIEW option 3.3.1 is not working for those upgraded system.
Release:
Component: OPSMVS
The DFSAOE00 and DFSAOUE0 modules in LinkList were not the OPS/MVS provided source members (absence of the OPSAOE00 and OPSAOUE0 eyecatchers), so it is necessary to re-assemble the current source members from the OPS/MVS CCLXASM dataset and replace the ones in LinkList.
We also reviewed the Identify IMS OPSVIEW option (7.4) to update the IMSnAOI and CMDOFFSET parameter values with the output generated from this utility. The OPS/MVS provided IMS exit module source code is downward compatable as they run both IMS v15 and v13.