The ems probe turns red/fails to start.
In the ems.log file, we see: "com.nimsoft.events.common.exception.EMSRestartException: Data Store Open Failed "
Jun 22 10:14:22:557 [main, ems] EMS - shutdownAndRestartCleanup end
Jun 22 10:16:27:288 [main, ems] Started quartz scheduler
Jun 22 10:16:30:968 [main, ems] ****************[ Booting ]****************
Jun 22 10:16:30:969 [main, ems] version 10.1.7
Jun 22 10:16:31:124 [main, ems] Probe exception: com.nimsoft.events.common.exception.EMSRestartException: Data Store Open Failed
DX UIM - Any Version
ems probe - any version
Possible EMS DB corruption.
Please do the following:
- deactivate the ems probe
- Delete ems db folder from the following location: <UIM_Installation>\Nimsoft\probes\service\ems\db
- activate the ems probe.
after you will see ems start properly.
In a future release of EMS (not yet determined as of November 2024) this will be detected by the probe and it will delete the db files itself in order to self-correct.