This may happen if module XCOMJOB is at a fix level greater or equal than RO99935 XCOMJOB STORAGE LEAK AFTER APPLYING RO96344 (ZDEC Support) and at the same time module XCOMCINT is at a fix level lower thanRO99490 LE NOT BEING PROPERLY TERMINATED WHEN XCOMJOB CALLED AS API. The symptom is a U4094-18 abend during XCOMJOB normal termination. For example:
08.08.28 JOB83908 NAXC86 REQ#=002000 ID=XCOMTEST XCOMM0373I ...............1508 536
536 BLOCKS ..............22866 RECORDS SENT - FILE=XCOM.TEST.FILE
08.08.28 JOB83908 IGD104I Q047166.XCOM.III.SEQF RETAINED, DDNAME=SYS00001
08.08.28 JOB83908 XCOMM0151I NAXC86 SESSION ENDED CID=02000040
08.08.28 JOB83908 XCOMM1168I PLEXQ LISTENER TASK STOPPING
08.08.28 JOB83908 XCOMM0015I NAXCGX00 ACB CLOSED SUCCESSFULLY
08.08.30 JOB83908 IEA794I SVC DUMP HAS CAPTURED: 544
544 DUMPID=001 REQUESTED BY JOB (XCOMTEST)
544 DUMP TITLE=SLIP DUMP ID=0001
08.08.30 JOB83908 CCSR010E XCOMSTSK U4094 at 066AEA5E LMOD CEEPLPKA CSECT N/A +N/A XCOMTEST N/A PVPRD0
08.08.30 JOB83908 CCSR061I PSW: 00000000 00000000 078D1000 866AEA5E
08.08.30 JOB83908 CCSR062I ILC: 02 INTERRUPT CODE: 0D
08.08.30 JOB83908 CCSR067I COMPLETION CODE U4094 REASON CODE 00000018
.....
08.08.31 JOB83908 XCOMM0071I XCOMJOB NOW TERMINATING
08.08.31 JOB83908 XCOMM0897I TOTAL ELIGIBLE zIIP TIME = 0 MICROSECONDS
08.08.31 JOB83908 XCOMM0897I TOTAL ACTUAL zIIP TIME = 0 MICROSECONDS
This abend should clear after applying fix RO99490 LE NOT BEING PROPERLY TERMINATED WHEN XCOMJOB CALLED AS API
Both fixes must be applied.