Multiple probes on a hub showing 'suspended' no queues working as a result but do have connectivity
book
Article ID: 102695
calendar_today
Updated On:
Products
DX Infrastructure Management
NIMSOFT PROBES
Show More
Show Less
Issue/Introduction
Multiple probes display as suspended under the 'Active' column in the Infrastructure Manager and probe icon appears white.
<Please see attached file for image>
Cause
Robot was placed into maintenance.
Environment
- UIM (any version)
Resolution
1. Open the controller probe
2. Select the Status Tab
3. Rt-click on the robot status icon button
4. Select the option 'Leave suspend mode now'
<Please see attached file for image>