CA Automic Workload Automation - Automation EngineAUTOMIC WORKLOAD AUTOMATION
Issue/Introduction
-The system message S0E0 Reason 28 Reserved bit positions in an access list entry token (ALET) were nonzero
-The offset where the program UCXJM25 aborted PSW AT TIME OF ERROR 078C4400 800C1526 ILC 6 INTC 28 ACTIVE LOAD MODULE ADDRESS=00007000 OFFSET=000BA526 NAME=UCXJM25 DATA AT PSW 000C1520 - D207B030 41685850 41041F66 AR/GR 0: 00000000/00000000 1: 00000000/00006278 2: FFFFFFFF/00000433 3: FFFFFFFF/000004FA 4: 00620003/007F509C 5: 00620003/00000000 6: 00620003/59CD10C7 7: FFFFFFFF/00F18700 8: FFFFFFFF/03D9A000 9: FFFFFFFF/0000628C A: FFFFFFFF/00006248 B: FFFFFFFF/3B682AB8 C: 00000000/000C1238 D: 00000000/3B682B00 E: 00000000/00006288 F: 00000000/00000000 END OF SYMPTOM DUMP
--
INTERRUPT OCCURRED AT ADDRESS 800C1520 LAST KNOWN I/O OR CALL OCCURRED AT ADDRESS 00B3B0F0 AT OFFSET +0000F0 IN MODULE CASESSIS THE Z/OS BREAKING EVENT ADDRESS IS 00000000 01611912 IN UNKNOWN PROGRAM
--
There may be an issue when trying to write within the CAIPRINT repository, please check the following to confirm:
The system abend of the started tasks is most probably a side effect (OEO reason 28) — this may not fix the issue.
3. ACTUAL: The Agent will activate the extended console, it ACTIVATES an extended console, it say successful, but a second later, when the Agent “inactivates” the event console the agent dies. The OS390 agent is using access registers without initializing them. We run with a list for DIAG traps successed by IBM to catch coding errors and need this corrected so we can pass out this agent to our systems. EXPECTED: The Agent stays active This console is only open if the 'defultJobClass' is not set wihin the INIfile of the agent.
Just set within the '(WLM)' section this parameter: f.ex.: (WLM) defultJobClass=C If this is set the function is scipped ($d intrdr,c) – this did not resolve the issue.
Environment
For this error, the following information is useful:
Capture of the abend JES log Agent log Agent trace (TCP/IP=9)
Resolution
Workaround:None available.
Resolution: Update to at least 12.0.2 Automation Engine/Components, but the latest release of 12.0.x or 12.2.x is recommended.