Datacom DATACOM - AD CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware

Issue/Introduction

We have this problem running DBUTLTY INIT on a newly added AREA/TABLE.
We receive message:

CSV003I REQUESTED MODULE 00000000 NOT FOUND 
CSV028I ABEND806-04 

Environment

z/OS  
CA Datacom 

Cause

The table definition was added in Datadictionary with User Compression-exit name 00000000 which cannot be found hence the S806 abend.

Resolution

 Remove the user compression-exit name in Datadictionary , put spaces ,  catalog the base and run the INIT.